| AC Input 90~264V |
DC Output |
| |
Voltage |
Current/A |
Watts |
| GPSU 15x- 0 |
3~5 |
2.40~1.44 |
7.2 |
| GPSU 15x- 1 |
5~6 |
2.40~2.00 |
12 |
| GPSU 15x- 2 |
6~8 |
2.00~1.50 |
12 |
| GPSU 15x- 3 |
8~11 |
1.80~1.36 |
15 |
| GPSU 15x- 4 |
11~13 |
1.36~1.15 |
15 |
| GPSU 15x- 5 |
13~16 |
1.15~0.94 |
15 |
| GPSU 15x- 6 |
16~21 |
0.94~0.72 |
15 |
| GPSU 15x- 7 |
21~27 |
0.72~0.55 |
15 |
| GPSU 15x- 8 |
27~33 |
0.55~0.45 |
15 |
| GPSU 15x- 9 |
33~48 |
0.45~0.31 |
15 |
ELECTRICAL SPECIFICATIONS:
- Input range : 90-264VAC (Full Range)
- Frequency : 47~63Hz
- Input current: 0.5 A MAX
- Safety ground leakage current : Class 1: 0.25mA Max. @ 240VAC/50 Hz
- Output power range: 15 watts max
- Avg. Efficiency : See rating chart
- Output voltage: See rating chart
- Output current : See rating chart
- Ripple: 1 % peak to peak maximum
- Protection: Over voltage protection(OVP) --AC recycle short circuit protection
Over Current Protection(OCP)-- Over Temparature Protection
ENVIRONMENTAL
- Operating temperature: 0°C to +40°C ambient
- Storage temperature:-40°C to +85°C
- MTBF : >10,000 hours at full load and 25°C ambient temperature
SAFETY
- (A) UL60950-1 CSA C22.2
- (B)EN60950-1 ; IEC60950-1
EMI
- (A)CE: EN 55022
- (B)FCC 47 CFR Part 15 Subpart B.
|
|
|
|
| |
|
|
|